ENGLISH
2. Address selection
ADDR = 00
Set both ‘ADDR’ rotary switches to ‘0’.
Every module in the system must have a unique address. When the Velbus
®
is not used, the address must be set to ‘00’ to
disable communication with the system.
Remove the cover
REMARK WHEN USING VELBUS:
Normally only 2 ‘TERM’ terminators
must be used in a complete Velbus
®
installation. Usually this will be on
one module inside the distribution
box and on the module which is
physically located furthest from the
distribution box.
On all other modules, the terminator
must be removed.